Fluorescence Multi-Detection Device #VitaiStream #Labtech_Holter #Pedcath8 #Arteriograph24 #Technosensor
Fluorescence Multi-Detection Device Using a Lensless Matrix Addressable microLED Array
by Victor Moro 1,*ORCID,Joan Canals 1ORCID,Sergio Moreno 1ORCID,Steffen Higgins-Wood 2ORCID,
Oscar Alonso 1,Andreas Waag 2,J. Daniel Prades 1,2 andAngel Dieguez 1,*ORCID
1
Electronic and Biomedical Engineering Department, University of Barcelona, 08028 Barcelona, Spain
2
Institute of Semiconductor Technology, Technical University of Braunschweig, 38106 Braunschweig, Germany
*
Authors to whom correspondence should be addressed.
Biosensors 2024, 14(6), 264; https://doi.org/10.3390/bios14060264
Submission received: 25 March 2024 / Revised: 29 April 2024 / Accepted: 21 May 2024 / Published: 22 May 2024
(This article belongs to the Special Issue Advanced Fluorescence Biosensors)
Downloadkeyboard_arrow_down Browse Figures Versions Notes
Abstract
A Point-of-Care system for molecular diagnosis (PoC-MD) is described, combining GaN and CMOS chips.
The device is a micro-system for fluorescence measurements, capable of analyzing
both intensity and lifetime. It consists of a hybrid micro-structure based on
a 32 × 32 matrix addressable GaN microLED array, with square LEDs of 50 μm edge length and
100 μm pitch, with an underneath wire bonded custom chip integrating their drivers and
placed face-to-face to an array of 16 × 16 single-photon avalanche diodes (SPADs) CMOS.
This approach replaces instrumentation based on lasers, bulky optical components, and
discrete electronics with a full hybrid micro-system, enabling measurements on 32 × 32 spots.
The reported system is suitable for long lifetime (>10 ns) fluorophores
with a limit of detection ~1/4 μM. Proof-of-concept measurements of
streptavidin conjugate Qdot? 605 and Amino PEG Qdot? 705 are demonstrated,
along with the device ability to detect both fluorophores in the same measurement.
Keywords: Point-of-Care; multiplex; microLED array; SPAD; fluorescence;
lifetime fluorescence; GaN; CMOS; microLED driver
1. Introduction